Tanaka Automatic Flash Point Testers

Abl-8 Automated ABEL Closed Cup Flash point Tester (IP 170, ISO 13736 etc)

labcon

The theme of the 8th generation is “Ergonomic, Versatile and Premium” Model abl-8 is an automated Abel Closed Cup flash point tester to cover flammable and combustible materials for shipping and safety regulations. Heating / cooling is by energy efficient Peltier modules attached to a metal block bath. Air-cooled model abl-8a and liquid cooled model abl-8 lare available for different temperature ranges. (Model abl-8l requires an optional chiller.)

Atg-8 Automated Tag Closed cup Flash Point Tester. (ASTM D56, IP 304 etc)

labcon

Based on 45 years of experience in manufacturing automated flash point testers, innovative 8th generation series has been released. The theme of the 8th generation is “Ergonomic, Versatile and Premium” Model atg-8 is an automated Tag Closed Cup flash point tester. In addition to model atg-8w with conventional water bath, model atg-8l with metal block bath is available for low temperature range. The cooling / heating for model atg-8l is by liquid cooled Peltier modules. (Model atg-8l requires an optional chiller.

apm-8 Automated Pensky-Martens Closed Cup Flash Point Tester (ASTM D93, IP34, ISO 2719 etc)

labcon

Based on 45 years of experience in manufacturing automated flash point testers, innovative 8th generation series has been released.The theme of the 8th generation is “Ergonomic, Versatile and Premium” Model apm-8 is an automated Pensky-Martens Closed Cup flash point tester. Three test procedures are built in for varied samples: Procedure-A for homogeneous petroleum liquids such as distillate fuels, Procedure-B for residual fuel oils and some other nonhomogeneous liquids, and Procedure-C for biodiesel.

Aco-8 Automated Cleveland Open Cup Flash Point Tester. (ASTM D92, IP36, ISO 2592 etc)

labcon

The theme of the 8th generation is “Ergonomic, Versatile and Premium” Model aco-8 is an automated Cleveland Open Cup (COC) flash & fire point tester. Gas test flame is ignited automatically. Fire point is determined automatically when sustaining combustion has been detected for 5 sec. Fire containment by a metallic lid covers the test cup automatically when a sustained fire is detected. Model aco-8as is for testing bituminous materials.

ACO-T602 Automated 6 Positions Cleveland Open Cup Flash Point tester. (ASTM D92, IP36, ISO 2592 etc)

labcon

ACO-T602 automatically carries out COC flash point test of up to 6 samples continuously.For large sample numbers, this carousel model reduces the burden on the laboratory personnel. Easy programming: Up to 6 types of sample data can be stored and later recalled for easy programming of routine tests. Electric ignition: Reliable, easy, and safe.