The MKC‑710B is a compact and cost-effective coulometric Karl Fischer moisture titrator designed for precise trace-level water content determination in solids, liquids, and gases. It’s part of KEM’s 7th-generation MKC‑710 series, offering fast and accurate measurements with a compact footprint and a straightforward user interface.
Type | Karl Fischer Moisture Titrator |
---|---|
Model | MKC-710B |
Standard configuration | MKC-710+IDP-100+Manual Solvent Change Unit |
Measuring method | Karl Fischer Coulometric titration |
Measuring range | Water content : 1ug to 300mg (depends on reagent) Bromine content : 8ug to 300mg *1 |
Measurement cell | 2-Component or 1-Component |
Precision | 0.1μg |
Control method | Constant current pulse time contro |
Endpoint detection | Alternate current polarization method with a twin platinum electrode |
EP sense method | Selective drift stability or limit measurement time |
Required solvent | 2-Component cell : Anolyte 100mL , Catholyte 5mL 1-Component cell : Anolyte 150mL |
Method | 20 |
Key operation | Sheet key |
Displays | 1) Black and white LED-backlit LCD 2) English / Japanese / Mandarin Chinese / Korean / Russian / Spanish 3) 1-channel display |
Calculation | Concentration of water content , statistics data processing (mean , SD and RSD) and automatic averaging of blank value and factor value |
Data storage | 100 samples |
GLP conformance | Registration of operator /Record of check results / Record of factor measurement / Management of conduction time |
External I/O | RS-232C port x2 : for Dot matrix printer , Electronic balance , Data Capture Software (SOFT-CAP)USB×1 : for USB flash drive , Thermal printer , Keyboard , Barcode reader , Foot switch , USB HUB , Android device |
Ambient condition | 1) Temperature : 5 to 35°C 2) Humidity : 85%RH or below (no condensation) |
Power source | AC100 to 240V +/- 10% 50/60 Hz |
Power consumption | Main unit : Approx. 20W Printer : Approx. 7W |
Dimensions | Titration unit : 141(W) x 292(D) x 244(H) mm Stirrer : 107(W) x 206(D) x 340(H) mm (not incl. Solvent Change unit) Solvent Change Unit : 240(W) x 140(D) x 405(H) mm (not incl. tubing) Printer : 106(W) x 180(D) x 88(H) mm |
Weight | Titration unit : Approx.3.0kg Stirrer : Approx.2.0kg Solvent Change Unit : Aprox.0.6kg Printer : Aprox.0.4kg |
Conformity standard | CE marking EMC : EN61326-1 LVD : EN61010-1 |
Make | KEM |
---|---|
Method | ASTM D1123, ASTM D1533, ASTM D3401, ASTM D4672, ASTM D4928, ASTM D5460, ASTM D6304, ASTM D6869, ASTM E1064, ISO 10101-3, ISO 12937, ISO 14897, ISO 15512, ISO 760, JIS C2101, JIS K0068, JIS K0113 |